This rough-in kit may be installed prior to choosing the specific trim and finish. Allows for construction or a renovation project to proceed without delays when narrowing down a design style. Trim kit is sold separately and is required to complete the unit. Save time, effort, and money on future renovation updates because there’s no need to alter plumbing behind the wall.
  • MultiChoice® Universal valve body rough-in kit only
  • Must purchase trim kit to complete the unit
  • Forged brass body
  • Three port diverter rough
  • Cartridge ships with trim
  • For use with (3) three or (6) six function diverter
  • For use with 3- or 6-setting Delta custom shower diverter trim
  • Pressure test cap allows for testing before installation
  • Backed by Delta Faucet’s Lifetime Limited Warranty
California Prop 65 WARNING
SUPPORT
Installation Information
Over All Height :
3-3/8
Connection Type :
NA
PART LIST
REVIEWS
Rated 5 out of 5 by from Bath Reno does the job as advertised
Date published: 2021-01-22
Rated 1 out of 5 by from Where’s the Hot and Cold... We installed the diverter assuming you can have either Hot or Cold. Can it be done with this diverter
Date published: 2021-01-12
Rated 5 out of 5 by from Necessary part [This review was collected as part of a promotion.] Part of shower system to work properly
Date published: 2021-01-08
Rated 5 out of 5 by from The best Beautiful and fully functional. Great flow and the bronze is incredible
Date published: 2020-11-24
Rated 5 out of 5 by from Deverter Work perfectly. Had some issues with paperwork but it works now.
Date published: 2020-11-17
Rated 5 out of 5 by from Delta quality Good quality product that installed easily and worked well
Date published: 2020-09-13
Rated 5 out of 5 by from Universal Part Great core plumbing piece. Easy to install and does fit the fixture as recommended
Date published: 2019-02-10
Rated 5 out of 5 by from Anther great Delta product Highly recommend. Easy to follow directions and easy installation. Will only buy Delta, they stand by their products. GREAT tech support.
Date published: 2019-02-02
  • y_2021, m_2, d_25, h_17
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.14
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_51
  • loc_en_US, sid_R11000, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_deltafaucet
  • bvseo_sdk, dw_cartridge, 18.2.0, p_sdk_3.2.0
  • CLOUD, getReviews, 7ms
  • reviews, product
Q&A

Can I make the valve control go to shower head or hand held but not both?

Asked by: Tony tucker
Thank you for your question, Tony! The Delta R11000 Diverter Rough-in will accept the RP71717 two setting, Non-Shared Diverter Cartridge which will diverter between both items without a shared function. https://www.deltafaucet.com/parts-product-detail?modelNumber=RP71717 Best regards, Edward
Answered by: Delta Faucet
Date published: 2020-02-13

What types and how many rough in valves will I need?

I am installing two fixed shower heads, a handheld, a rain shower, and 2 sets of body sprays (3 each with different on/off controls) in my master bath. I was told that one R10000 UNBX valve and one R11000 3/6 diverter would be sufficient. However, my plumber advised that would not work and its better to have more diverters because when I want to run multiple items at once, the pressure will be extremely low where I will be getting only drops of water. I want to be able to run a max of 3 items at one time without any water flow/pressure loss. What types and how many rough in valves will I need?
Asked by: Milz
Dear Milz, Thank you for your question. To install your two fixed shower heads, a handheld, a rain shower, and 2 sets of body sprays you would need two of the Delta MultiChoice Rough-In Valve R10000-UNHF and two of the Delta Delta 3 / 6-Setting Diverter Rough-In Valves R11000. Best regards, Tanya
Answered by: Tanya
Date published: 2017-04-10

can you get this valve w/stops?

Asked by: Nicole
Hi, Nicole! Thank you for your question. The Delta R11000 diverter valve does not come with stops as this does not flow of the water. This diverts water from one shower component to the other. Best Regards, Rosanna
Answered by: DeltaFaucet11
Date published: 2019-01-04

how to make water flow though port 3 left side instead of port 2 in right side?

Asked by: kghome
Thank you for your question, kghome! The right port of the R11000 valve should be plugged when using a 3-setting diverter cartridge. If you are using a 6-setting cartridge and trim, the diverter handle will allow water to flow through the right port. Please refer to the maintenance and installation manual below for reference. https://media.deltafaucet.com/MandI/70551%20Rev%20F.pdf Best regards, Edward
Answered by: Delta Faucet
Date published: 2019-06-14

I am doing wall shower on right rain shower on top and wall shower on left . I am confused why do I have to cap right for three function

if i ca right side as it says on the valve how do i install my hand shower on right>
Asked by: gary
Hi Gary, Thank you for your question. You will only need to cap the right side of the valve if you will be using a 3-setting trim kit. For your set up, you will need to use a 6-setting trim kit and will not have to cap the valve. Best Regards, Courtney
Answered by: DeltaFaucet12
Date published: 2016-06-27

R11000 GPM Flow Rate

I want to install (4) body jets and need to ensure the flow rate from the diverter is as high as possible. I will use a 6 setting cartridge/trim. What is the GPM of this unit at 60 and 80 PSI of water pressure: 1) when water is dedicated to one port; and 2) when water is shared between two ports?
Asked by: ShowerBuild
Hi ShowerBuild Thank you for your question. The flow rate will be primarily determined by the main valve and trim that you use (R10000 + 13/14, 17, or 17T trim). The approximate maximum flow rate from the diverter valve at 60 PSI is: With R10000-UNBX: 14 series - 5.8 GPM 17 series - 5.9 GPM 17T series - 7.3 GPM With R10000-UNBXHF (High-Flow): 14 series - 6.3 GPM 17 series - 6.6 GPM 17T series - 8.6 GPM At 80 PSI the flow rate is increased by approximately 1 GPM. These are the maximum total flow rates from the diverter valve in a shared position. The maximum flow from an individual diverter port is limited to 5 to 6 gallons per minute, depending on pressure and the trim series chosen. Best regards, Jon
Answered by: DeltaFaucet3
Date published: 2018-01-16

I am installing an R11000 diverter and only want to have a fixed shower head and a hand held. Do i use the top and left side outlets on the R11000 and plug the right outlet? Which cartridge do I need to run the fixed shower head and the hand independently

Asked by: David
Thank you for your question, David! In order to use an R11000 diverting valve for a shower head and hand shower, you will need to cap the right port and use either a 3-setting RP51918 cartridge that has two individual settings and one shared setting or the RP71717 non-shared cartridge which offers two individual settings only. https://www.deltafaucet.com/parts-product-detail?modelNumber=RP51918 https://www.deltafaucet.com/parts-product-detail?modelNumber=RP71717 Best regards, Edward
Answered by: DeltaFaucet234
Date published: 2019-01-02

The mounting instructions are very unclear, how deep from the finished tile surface does the diverter need to be set?

Mounting a stringer along the back plane of the studs seems to leave the housing out too far for the trim plate to sit flush
Asked by: David
The instructions that COME with the diverter are clear, they are just wrong. They say 3 1/4" inches from stringer to finished wall which means you'd need to use a pretty thin stringer. That would also mean the inlet wouldn't align with the outlet of the R10000 valve below it if you were mounting the diverter above which is common. The instructions confused the heck out of me as well which is why I took to the internet. The instructions here online say 2 3/4" inch from stringer to finished wall. Aha! Makes much more sense. Hey Delta, you do cite the finished wall thickness has a pretty big degree of thicknesses it's compatible with, but being a half inch off on a mounting depth is pretty bad. Was that just a typo? I'm mounting the R10000 and R11000 both to 2x4 stringers in a standard depth 2x4 wall space with 1/2" Durock backer board and 1/4" thick tile with ~1/8 inch of thinset / roll on sealer in between them. My measurements put everything exactly where it needs to be...
Answered by: bigrobintexas
Date published: 2016-04-13
  • y_2021, m_2, d_25, h_17CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.14
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_182
  • loc_en_US, sid_R11000, prod, sort_[SortEntry(order=HAS_STAFF_ANSWERS, direction=DESCENDING)]
  • clientName_deltafaucet
  • bvseo_sdk, dw_cartridge, 18.2.0, p_sdk_3.2.0
  • CLOUD, getContent, 50ms
  • questions, product
Mike and Hanna
Delta logo thumb

Need help with installation? Mike & Hannah are here to help! Get advice from the pros on everything from installation to product care.

Delta BiLT app
BiltLogo IntelligentInstructions Horizontal

Installation made easy. Download the free BILT app to access step-by-step 3D interactive instructions.

* Actual pricing may vary and is determined by the selling retailer/wholesaler/dealer.