The spool and sleeve, the part of the Monitor pressure balance valve that blends the hot and cold water, may not be working properly. This is often caused by mineral deposits that build up over time. To solve, follow the steps below based on your model.

Tools you may need:

installhotcoldtools
  1. Shut off water supply.

    installhotcold1
  2. There are two types of valves. Choose a or b below depending on your series

    1. 1300/1400 Series: Remove handle.

    2. 1700/1800 Series: Remove temperature knob, cover and handle.

  3. Twist and pull sleeve to remove it.

  4. Unscrew brass bonnet nut.

  5. Remove cartridge.

  6. Soak cartridge in a 50/50 vinegar and water solution for 24 hours to remove any mineral deposits.

NOTE: Unless both hot and cold water supplies are turned on, the pressure balance valve will allow only a dribble of water to flow through the valve.

Helpful Hints:

  1. Before removing valve cartridge assembly for any maintenance, be sure to note the position of the stop on the cap. The valve cartridge assembly must always be put back in the same position. For normal installations, the stop on the cap will face the left.

    BE SAFE! After you have finished the installation, turn on valve to make sure COLD WATER FLOWS FIRST.

  2. To remove valve cartridge from body, shut off water supplies and remove handle and bonnet nut. Do not pry the valve cartridge out of the body with a screwdriver. Place handle on stem and rotate counterclockwise approximately 1/4 turn after the stop has been contacted. Lift valve cartridge out of body
  3. To remove seats and springs, remove valve cartridge. Separate cap assembly from the housing assembly by rotating the cap assembly counterclockwise 90 degrees. Separate cap and housing assemblies. Remove seats and springs and replace. Place the largest diameter of the spring into the seat pocket first and then press the tapered end of the seal over the spring. Reassemble valve cartridge and replace in body following instructions given in 1 above.
  4. If the water in your area has lime, rust, sand or other contaminants in it, your pressure balance valve will require periodic inspection. The frequency of the inspection will depend on the amount of contaminants in the water. To inspect valve cartridge remove it and follow the steps in note 1 above. Turn the valve to the full mix position and shake the cartridge vigorously. If there is a rattling sound, the unit is functional and can be reinstalled following instructions given in note 1 above. If there is no rattle,replace the housing assembly (RP19805).