how does the cartridge work with the shower handle? does the cartridge turn the shower on/off?or just the handle?
Asked by: Keith
Thank you for your question, Keith! The valve assembly cartridge contains a mixing chamber with two inlet ports for hot and cold water to enter. When the handle is turned, it also turn the cartridge and opens the valves to allow a mixture of water inside. The temperature knob will then give further control of the preferred temperature.
Best regards, Edward
Answered by: Delta Faucet
Date published: 2024-03-28
Low pressure from shower head after replacing cartridge RP46463
I replaced both the cartridge & plastic adapter, now flow coming out of shower head is very low.
Asked by: Rsijder
Hi Rsijder, Thank you for your question. We would recommend removing the showerhead itself and turning on the faucet to check flow and flush the line to the showerhead. Make sure that the debris screen in the showerhead is clean. To rule out the cartridge as the problem we recommend installing the RP46078 test plug and turning on the water supply to the faucet to check flow. If everything alse checks out the cartridge would need to be replaced.
http://www.deltafaucet.com/repairparts/details/rp46078.html
Thanks,
Dave
Answered by: DeltaFaucet2
Date published: 2024-03-28
I need to download & print the specs for this cartridge for a building inspector but when i click on Documents & Specs nothing comes up that i can open & print out. Also would this cartridge be interchangeable with Brizo RP75213
Asked by: Dave
Hi, Dave!
Thank you for your question. Here is a link to the instruction manual for the Monitor 17 series unit that the RP46463 valve cartridge assembly works with:
https://media.deltafaucet.com/MandI/76652%20Rev%20G.pdf
The RP75213 is not interchangeable with the RP46463.
Best Regards,
Rosanna
Answered by: DeltaFaucet11
Date published: 2024-03-28
Does this part work for the 1300/1400 series from a home built in 1999?
My home was built in 1999 using nothing but Delta products. All have held up extremely well except for my upstairs bathtub faucet which ironically is the one used the least. It began leaking profusely from the handle and when I removed it, the cap was cracked and broken in two different places. Since it was builder installed, I do not have part numbers. I went to a plumbing supply company and they provided me with replacement part #RP46463 but it says for cartridges made after 2005. I am trying to determine if this part will work for my faucet before calling a plumber to install it. Thanks.
Asked by: Texas
Thank you for your question, and let me first apologize for the issue that you are experiencing. We do love to hear of a house built of nothing but Delta Faucets and are excited to offer a fix! Delta part #RP46463 is for our 1700 Multichoice valves. The part we will recommend to you for a 1300/1400 series (circa 1999) is Delta part #RP19804.
Answered by: Delta
Date published: 2024-03-28
i have a monitor 17 series the faucet is leaking
I went to the plumbing store and the part he gave me was RP16208 is this correct?
Asked by: sue
Hi Sue, Thank you for your question. The RP16208 repair kit should stop the faucet leak in your 17 series faucet.
Thanks,
Dave
Answered by: DeltaFaucet2
Date published: 2024-03-28
How do I remove old cartridge rp32104
Asked by: Bart757
Thank you for your question, Bart757! The RP32104 cartridge can be removed once the water is turned off to the room, unit or home. The bonnet nut that holds the cartridge in place must first be unscrewed counter clockwise and then the cartridge will pull straight out. Please know that if you have an older 1300/1400 series valve body, the newer Multichoice 13/14 series cartridge, as well as the 17 series cartridge RP46463 will not fit into this valve body.
Best regards, Edward
Answered by: Delta Faucet
Date published: 2024-03-28
Can I Convert 1400 to 1700 without rough in
My home was build in 2000 it got a delta 1400 series single knob in the shower. I want an temperature control upgrade t17053 look without getting a rough in kit is that possible. I seen a video all I need was a different cartridge kit
Asked by: Vik
Hi Vik, Thank you for your question!
In March of "2006" we manufactured a universal valve body model R10000-UN that allows any of our current trims to interchange. If you have the universal valve you will be able to change your 13/1400 series with one control for volume and temperature to our 17 series that has separate volume and temperature control. However, your unit was manufactured prior to March of "2006" you have an older valve body and will not be able to change your trim to our dual control trim. You will only be able to use any current T13 or T14 series trim but will not be able to use the new universal valve cartridge that comes with the new trims.
Best regards, Brandis
Answered by: DeltaFaucet7
Date published: 2024-03-28
Does Delta have a High Flow Replacement Cartridge for the Multichoice 17 Series Shower / Tub Valve (RP46463).
Asked by: Gee55
1 1/2 hour wait time when calling 1-800 number! Good Luck!
Answered by: Guy65
Date published: 2024-11-11
Is there an instruction regaling how to replace the valve? Maybe a YouTube video? Thanks!
Asked by: Darko
Thank you for your question, Darko! Unfortunately, we do not have a video for installing the RP46463 valve cartridge assembly, at this time. Turn off water supplies. Remove the cover bonnet nut from the body. Insert adapter assembly into valve body. Make sure the adapter assembly is correctly positioned and is pressed all the way down inside body. Remove the retainer from the adapter. Rotate cartridge so the words “HOT SIDE” appear on the left. Insert cartridge assembly into valve body. Make sure the key on the cartridge is fully engaged with the slot in the brass body. Slide bonnet nut over the cartridge and thread onto the body. Hand tighten the bonnet securely. If you need further assistance, please feel free to call, email, or message us on social.
https://media.deltafaucet.com/MandI/102477%20Rev%20A.pdf
Best regards,
Tanya
Phone: 1-800-345-3358 | Email: customerservice@deltafaucet.com | Facebook/Twitter: @deltafaucet
Answered by: Delta Faucet
Date published: 2024-03-28
would this be the correct replacement part for a T179097 cassidy series? does this include the rp46073 cartridge? thanks
Asked by: dave
Hi, Dave!
Thank you for your question. The Delta RP46463 Valve Cartridge Assembly does include the RP46073 Adapter Assembly and does work with the Monitor T17097 Valve Trim Kit.
Best Regards,
Rosanna
Answered by: Delta Faucet
Date published: 2024-03-28
Does the RP46463 Cartridge assembly mulitchoice universal 17-series come with the Dryden shower faucet trim kit T17251-SP or do i need to order it separately?
Asked by: Joan
Hi, Joan!
Thank you for your question. The Delta Monitor T17251-SP Shower Faucet does include the Delta RP46463 Valve Cartridge Assembly.
Best Regards,
Rosanna
Answered by: Delta Faucet
Date published: 2024-03-28
can i replace this valve with brass high flow cartridge?
Asked by: Frankie52
Thank you for your question, Frankie52! The RP47201 cartridge will fit into a current Multi-Choice Universal valve body, however, you would need to install a T17T series trim kit, which will include this cartridge.
Best regards, Edward
Answered by: Delta Faucet
Date published: 2024-03-28
Where do I find the install instructions for this model?
Asked by: David Luz
Hi, David!
Thank you for your question. Here is a link to the Maintenance and Instruction manual for the Delta Monitor 17 Series Faucet that features the RP46463 Valve Cartridge Assembly:
https://media.deltafaucet.com/MandI/102477%20Rev%20A.pdf
Best Regards,
Rosanna
Answered by: Delta Faucet
Date published: 2024-03-28
What's the rough in valve for cartridge RP32104?
I have an older model shower (faucet & head), Delta Monitor 1700 series, that uses RP32104 cartridge. Recently I found out that the rough in valve needs replacement.
What is the rough in valve for my cartridge?
Asked by: Fari
Hi Fari, Thank you for your question. The rough in valve used on your 1700 series faucet is no longer available. The replacement rough that can be used with your existing trim would be the R10000. You will also need to order the RP46463 cartridge to work in the new rough in.
Thanks,
Dave
Answered by: DeltaFaucet2
Date published: 2024-03-28
Water flow stop position incorrect
I have to turn the volume control back 10 degrees or so to stop it dripping. If the cartridge needs to be re-installed, are special tools needed to extract it? I have downloaded the Installation Guide Owner's manual, but it is not clear to me how to correct my problem. The unit was installed about a year ago and has been used only occasionally. I noticed just a few weeks ago that it was dripping quite significantly when turned in the fully off position.
Asked by: Ron
Hi Ron, Thank you for your question. You will not need any special tools to change out the cartridge but you will have to shut your water off. I have attached a link to the How to video for changing out the cartridge below. Your model is about 2:30 into the video.
Thanks,
Dave
http://www.deltafaucet.com/shopping-tools/research/video-gallery/video.html?v=tyUaPOBcuLY&cat=
Answered by: DeltaFaucet2
Date published: 2024-03-28
Adapt RP46463 for new single handle valve trim kit (Trinsic)
I have the Monitor series 2 handle valve (1999 home). The current cartridge is RP46463. I want to change to a single handle 1400 series handle and trim (trinsic). The RP19804 does not fit in my 1999 rough in valve body. Is there an adapter so I can use my RP46463 on a single handle valve and trim kit or is there another cartridge that will work with my rough in and operate my new single handle 1400 series trinsic trim kit? See pictures please.
Asked by: Rob
Hi Rob, Thank you for your question. Unfortunately there is not a way to convert your 1999 1700 series faucet that uses the RP32104 cartridge to a new single function trim or cartridge. The entire faucet including the rough in valve would have to be replaced.
Our faucets manufactured since February 2006 use the R10000 multi-choice universal rough that would allow you to switch between the T13/T14 single handle trims and the T17 trims that allow control over both temperature and volume.
Thanks,
Dave
Answered by: DeltaFaucet2
Date published: 2024-03-28
What is the part # for the large o-ring on the cartridge?
Asked by: Gary
Hello Gary!
Thank you for your question. The RP46463 valve cartridge assembly uses the RP23357 O-ring.
Best Regards, Shontay
Answered by: DeltaFaucet7
Date published: 2024-03-28
is there a new or replacement part for # RP46463
Lowes says they do not have this part but have a replacement part. Does not look the same.
Asked by: John
Hi John,
Thank you for your question. RP46463 is the current part number for this cartridge. We do not have a replacement for it. 1700 series faucets made prior to Sept. 2006 use the RP32104.
Best regards,
Jon
Answered by: DeltaFaucet3
Date published: 2024-03-28
Needing new faucet
I am wanting to upgrade our shower faucets in the house. They all currently have the RP32104 cartridge installed. I am needing to know if I can replace that cartridge with any other models in order to update our shower fixtures. Was wondering if I can just install the RP46463 and buy new faucet?
Asked by: J.R.
Hi J.R., Thank you for your question. The RP32104 cartridge was/is used on our 1700 series faucets. That is the only cartridge that will fit your existing rough in valve. You can order one of our new 17 series trims to work with your existing rough. The new trim will ship with a RP46463 cartridge. This cartridge will not fit your existing rough, you will continue to use the existing cartridge or order a new RP32104.
Thanks,
Dave
Answered by: DeltaFaucet2
Date published: 2024-03-28
R10000-UNBX gpm
We have a brand new house. I have a universal valve R10000-UNBX and the 17 series faucet with a RP46463 cartridge. I read the specs that say i should have "60 PSI will give you 6.3 gpm to the tub spout and 6.04 gpm to the showerhead".
i have 80 psi, the tub is 3 gpm and the shower 2 gpm.
i took the spout off and the bare pipe is 3gpm.
My tankless water heater shuts off due to the pressure balancing valve, or i think that is what is happening. How do i get the 6gpm you claim should be coming through this valve?
Asked by: mrbill
Hi MrBill,
Thank you for your question. Usually with tankless water heaters that are not kicking on to produce the water that you require, we recommend that you turn the water heater slightly to allow it to kick on more frequently.
Thanks.
Jody
Answered by: Delta1
Date published: 2015-01-16
what faucet turn nozzle do we use with this part. We bought one and it's wrong or doesn't work very very unhappy.
Asked by: ashleigh
Dear Asker Ashliegh,
Thank you for your question. I will be more than happy to help you. I have reached out to you via email to assist you with this.
Best Regards,
Samantha
Phone: 1-800-345-3358 | Email: customerservice@deltafaucet.com
Answered by: DeltaFaucet7
Date published: 2024-03-28
I have the series of 1700 Monitor single handle shower /faucet. what is the RP# for assembly cartridge?
Asked by: diamond4ever
Hi, diamond4ever!
Thank you for your question. The Delta Monitor 1700 series installed before 2006 will use RP32104 valve cartridge assembly. The Delta Monitor 17 Series installed after 2006 and uses the MultiChoice Universal R10000 rough valve body uses RP46463 valve cartridge assembly.
Best Regards,
Rosanna
Answered by: Delta Faucet
Date published: 2024-03-28
what is the part number for the large o ring around the outside of the RP46463 cartridge?
Asked by: Anonymous
Thank you for your question, RobZema! The RP46463 valve cartridge assembly uses the RP23357 O-ring.
https://www.deltafaucet.com/parts-product-detail?modelNumber=RP23357
Best regards, Edward
Answered by: Delta Faucet
Date published: 2024-03-28
Contractor just installed new shower using the Series 17. When I turn the water on hot and cold are reversed.
When I move the temperature control to the left for hot it becomes cold and vice versa. Thanks.
Asked by: Mike
Hi Mike, Thank you for your question. The RP46463 cartridge in your 17 series faucet is installed upside down. Removing the cartridge, rotating it 180 degrees and reinstalling the cartridge should solve your issue. Make sure the words "hot side" on the cartridge match up with your hot water supply side.
Thanks,
Dave
Answered by: DeltaFaucet2
Date published: 2024-03-28
What is the size and length of the handle screw and thread type?
Asked by: Tomb
Thank you for your question, Tomb! The length of the RP32105 screw is 3/4". The exact size of this screw is a #10-24 x .75.
Best regards, Edward
Answered by: Delta Faucet
Date published: 2024-03-28
All of a sudden I have to increase the temp selectoe to achieve the same temp I had with the lever at the mid point. The supply temp has not changed.
Asked by: Joe
Thank you for your question. Delta Faucet model # RP46463 can be affected by the temperature of your ground water coming into your house. Your rotational limt stop may need adjusting from time to time due to the change in seasons.
Included here are the maintenance and installation instructions for adjusting your rotational limit stop to allow more hot water to come through your valve. The directions are on page 9.
http://www.deltafaucet.com/customersupport/documentation/t17430.html?document=mi&documentIndex=0#flashWrapper
Answered by: Delta1
Date published: 2024-03-28
Our shower handle spins all the way around and won’t stop like it used to. Does a broken valve cause this?
Asked by: Chris
Hi, Thank you for contacting us.
We apologize for any inconvenience. We are more than happy to help you.
To better assist you, we would like to gather some more information first. Could you please provide your full name, address, phone number, model number and date of install.
Please contact us at 1-800-345-3358 if you have any further concerns. We are open Monday through Friday 7:00 AM to 7:00 PM central time, and 8:00 AM to 5:00 PM on Saturday.
Best Regards,
Bethany
Answered by: DeltaFaucet7
Date published: 2024-03-28
RP46463 vs RP32104 compatible?
I have an RP46463 that is leaking out of shower head constantly. No one seems to carry the RP46463 but the RP32104 is readily available. The box says compatible with 1700 series. The cartidge looks similar without the hot and cold seals part.
Asked by: zac
Hi Zac, Thank you for your question. The RP46463 and the RP32104 are not interchangeable. The RP32104 was used in our 1700 series faucets until February 2006. Our multichoice universal rough in was introduced in February 2006 and the 17 series faucets since that time have used the RP46463. You can order this cartridge from your local retailer or wholesaler that sells Delta products. You can also order online at deltafaucet.com. Here is the link.
http://www.deltafaucet.com/repairparts/details/rp46463.html?showPhotoGallery=false
Thanks,
Dave
Answered by: DeltaFaucet2
Date published: 2024-03-28
Shower valve is dripping-on the escutcheon it says "Delta Monitor 17 Multichoice". What cartridge number or repair kit number should I purchase? Thanks, Richard
Asked by: Rich
Hi Rich,
Thank you for your question about the Delta Faucet RP46463.
For a 17 series shower dripping while off, we recommend replacing the adapter RP46073. The rubber seats can wear or be damaged over time. If the issue remains, the RP46463 cartridge may need to be replaced.
https://www.deltafaucet.com/parts/product/RP46073.html
Please reach out with any additional questions!
Best Regards,
Bryan
Digital Communications Specialist
Answered by: Customer Service
Date published: 2024-10-22
Will you please provide a graph of flow rate vs inlet pressure?
Asked by: DGee
Hi Valued Customer,
Thank you for your question, please accept our sincere apology for the inconvenience you are experiencing. We will be happy to assist you in resolving this issue as quickly as possible.
Unfortunately, we do not offer a graph or inlet sheet.
Please feel free to contact us directly for technical or warranty information at 800-345-3358. We are available Monday through Friday from 8 a.m. to 8 p.m. and Saturdays from 9 a.m. to 6 p.m. Eastern Standard Time.
Thank you for being a loyal Delta Faucet customer.
Best Regards,
Themar
Digital Communications Specialist
Answered by: Themar
Date published: 2025-12-18